Hi Norbert,
try to swap the sequence of --resolution and --mode on the command line.
It is a known problem of the hp-backend that the command line keywords
are position dependent.
--Peter
Norbert Koch wrote:
>
> Hello.
> I am using an HP Scanjet IIcx with sane 1.0.2 under FreeBDS 4.0.
> When trying different resolutions I find the following:
> --mode Lineart --resolution xxx works ok.
> (At least I see different file sizes for different resolutions)
> For modes Color and Grayscale I always get the same resolution (300dpi ?).
> The hardware resolution of this scanner is 400dpi.
> Any idea?
>
> Norbert Koch
>
> --
> Source code, list archive, and docs: http://www.mostang.com/sane/
> To unsubscribe: echo unsubscribe sane-devel | mail majordomo@mostang.com
-- Peter Kirchgessner WWW: http://www.kirchgessner.net e-mail: peter@kirchgessner.net-- Source code, list archive, and docs: http://www.mostang.com/sane/ To unsubscribe: echo unsubscribe sane-devel | mail majordomo@mostang.com
This archive was generated by hypermail 2b29 : Mon Jul 10 2000 - 11:03:12 PDT