Re: [dev] microtek2 backend for SANE-1.0.5 ready for testing

From: Novak Levente (lnovak@dragon.klte.hu)
Date: Fri May 18 2001 - 01:56:40 PDT

  • Next message: lee: "Re: canon"

    On Thu, 17 May 2001, Karsten Festag wrote:

    > Hi all microtek-scanner users,
    > I think I have done enough modifications to the microtek2-backend so it
    > could be included in SANE-1.0.5. But I would like if many people would
    > test it and tell me about the results.
    >
    > the following scanners should be supported now additionally:
    >
    > Phantom 330CX / 336CX / SlimScan C3 (parallelport)
    > Phantom 636CX (parallelport)
    > Scanmaker V6USL (USB)
    > ScanMaker E3 Plus (parallelport)
    > Scanport SQ300 (parallelport) (recognized as Phantom)
    >
    > Please test the backend also with scanners that were working before. I
    > changed a lot of things and perhaps I've broken something.
    >
    > The backend can be downloaded at:
    > http://home.t-online.de/home/karsten.festag
    >
    > The version from today (17.05.2001) is microtek2_20010517.tar.gz. If
    > there are newer ones, take the newest version.
    >

    Hi,

    I haven't found any problems for the Phantom 636cx with a quick test
    (lineart, gray8bit, gray12bit, colour8bit, colour12bit, both at 150dpi on
    a 10x15 cm format glossy photograph, placed excentrically on the glass).

    Concerning the docs, I think also that it would be good to update the
    man-page. You coulde.g. list the parallelport and USB scanners working
    with this backend release.

    Also, I've found (this is probably a different issue though) that when
    GNOME 1.4 is i18n-enabled with Hungarian as default locale (haven't tried
    with others), the option backend-calibration and no-backtrace don't appear
    in Xsane's extended options window (nor elsewhere). You could maybe put a
    short sentence into the manpage that one can experience strange problems
    when using (some?) locale(s). It took me some time to discover that the
    bug was caused by the localisation and not this specific backend release.

    Finally, I propose to remove the line "parallelport models unsupported"
    at the SANE compatibility page. This was not really true even before, as
    several SCSI-over-parport scanners could be operated without image
    calibration even in Sane 1.0.1.

    Levente

    --