Peter Kirchgessner wrote:
>
> Hello Nicholas,
>
> it seems that the scanner does not respond to some of the very first
> inquire commands. It recognized as an HP scanner because otherwise it
> would have failed earlier.
> Maybe it is a timing problem.
This doesn't seem quite right coz...
> > [hp] scsi_inquire: sending INQUIRE
> > [hp] scsi_new: sending TEST_UNIT_READY
> > [hp] scsi_flush: writing 2 bytes:
> > 0x0000 1B 45 .E
> > [hp] scsi_flush: writing 7 bytes:
> > 0x0000 1B 2A 73 32 35 37 45 .*s257E
> > [hp] scsi_read: 0 bytes:
> > [hp] scl_inq: malformed response: expected 's257d', got ''
Here it appears to test for the version, and gets s257E instead of
s257d, and then...
> > [hp] scl_errcheck: Can't read SCL error stack: Error during device I/O
> > [hp] sanei_hp_device_new: SCL reset failed
erroneously goes on to treat it as a SCSI error.
Cheers,
Ben.
-- SECURE HOSTING AT THE BUNKER! http://www.thebunker.net/hosting.htmhttp://www.apache-ssl.org/ben.html
"My grandfather once told me that there are two kinds of people: those who work and those who take the credit. He told me to try to be in the first group; there was less competition there." - Indira Gandhi
-- Source code, list archive, and docs: http://www.mostang.com/sane/ To unsubscribe: echo unsubscribe sane-devel | mail majordomo@mostang.com
This archive was generated by hypermail 2b29 : Sat Jan 15 2000 - 06:04:47 PST