Luca Del Signore wrote:
>
> "Dr. Andreas Bolsch" wrote:
> >
> > An "=" sign, i.e. SANE_DEBUG_SCSI=128, not a "-".
>
> Well Dr.Bolsch,
> I did what you told me to do
> export SANE_DEBUG_SCSI=128
> export SANE_DEBUG_ARTEC=128
> /usr/local/bin/scanimage -d artec:/dev/scanner --mode gray --resolution
> 10 > /dev/null
> I enclose the output (scanimage debug.txt) and i hope it will be
> helpful!!
> Thanks in advance... :)))
> Luca Del Signore
> >
> > --
> > Source code, list archive, and docs: http://www.mostang.com/sane/
> > To unsubscribe: echo unsubscribe sane-devel | mail majordomo@mostang.com
>
> --
> Source code, list archive, and docs: http://www.mostang.com/sane/
> To unsubscribe: echo unsubscribe sane-devel | mail majordomo@mostang.com
--------------9EB63461E9ABF502DBD31BC9
Content-Type: text/plain; charset=us-ascii;
name="scanimage debug.txt"
Content-Transfer-Encoding: 7bit
Content-Disposition: inline;
filename="scanimage debug.txt"
*** Every line begins with [artec] : i omitted while writing the output down on paper cos otherwise it could take a lifetime...
[sane_init_debug] setting debug level of artec to 128
attach_one
Artec/ultima backend version 0.3 last mod. 10/18/1998 22:45
http://www4.infi.net/`cpinkham/sane/sane-artec-doc.html
attach: opening /dev/sga
attach:sending INQUIRY
attach: wait for scanner to come ready
wait_ready
scanner does NOT support read capability data function
attach: getting scanner capability data
Scanner compatibility info
Vendor : ULTIMA
Model: AT3
Type: flatbed
Width: 8.50 inches
Height: 11 inches
x-range: 0-215
y-range: 0-279
Horiz. DPI: 50-300
Vert DPI: 50-600
Contrast: 0-255
Req. Sh. Cal. : 1
Req. Ln Offs: 1
Req. Ch Shft: 1
SetWindSize: 55
Calib Method: 0
Attach: found ULTIMA AT3 version 1,90 x=0-14149222 y=0-18310758
X res = 50-300 dpi
Y res = 50-600 dpi
Attach_one
Artec/ultima backend version 0.3 last mod. 10/18/1998 22:45
http://www4.infi.net/`cpinkham/sane/sane-artec-doc.html
attach: opening /dev/sga
attach:sending INQUIRY
attach: wait for scanner to come ready
wait_ready
scanner does NOT support read capability data function
attach: getting scanner capability data
Scanner compatibility info
Vendor : ULTIMA
Model: AT3
Type: flatbed
Width: 8.50 inches
Height: 11 inches
x-range: 0-215
y-range: 0-279
Horiz. DPI: 50-300
Vert DPI: 50-600
Contrast: 0-255
Req. Sh. Cal. : 1
Req. Ln Offs: 1
Req. Ch Shft: 1
SetWindSize: 55
Calib Method: 0
Attach: found ULTIMA AT3 version 1,90 x=0-14149222 y=0-18310758
X res = 50-300 dpi
Y res = 50-600 dpi
Sane_open
Init: options
Sane_control_option 0, get value
Sane_control_option 0, get value
Sane_control_option 12, get value
Sane-control_option 13, get value
Sane_control_option 10, get value
Sane_control_option 11, get value
Sane_control-option 2, set value
Sane-control_option 3, set value
Scanimage: setting of option -resolution failed (invalid argument)
Sane_exit
--------------9EB63461E9ABF502DBD31BC9--