I suspect its bad netiquette to reply to your own post
but here goes...
...just re-read my previous message and realised
the two parameters I was changing are mentioned
in the dump file I posted.
They are (of course)
----- Original Message -----
From: "Jet Set Willy" <jsw@manic-miner.freeserve.co.uk>
To: <sane-devel@mostang.com>
Sent: Monday, May 21, 2001 10:40 AM
Subject: Re: Agfa StudioScan IIsi [long]
> An update....
>
>
> <snipped stuff about getting the Error Message:
> sane_start: Error during device I/O>
>
> I have tried to updrade to the latest version of sane but got an
> error message....
>
> only packages with major numbers <= 3 are supported by this version
> of rpm
>
> ... so I gave up on that an tried the suggestions given re the debug level
> which produced the following output which to be honest I can't make
> head nor tail of and am hoping that somebody here can :-)
>
> apologies if there is too much info here - guess I could have snipped
> most of it except the last 20 or so lines but wasn't sure.
>
> [sanei_init_debug]: Setting debug level of microtek to 255.
> [microtek] sane_init: MICROTEK says hello! (v0.12.0)
> [microtek] sane_init: config- # Uncomment following line to disable "real
> calibration" routines...
> [microtek] sane_init: config- #norealcal
> [microtek] sane_init: config- # Uncomment following line to disable
"clever
> precalibration" routines...
> [microtek] sane_init: config- #noprecal
> [microtek] sane_init: config- # Using "norealcal" will revert backend
to
> pre-0.11.0 calibration code.
> [microtek] sane_init: config-
> [microtek] sane_init: config- #original 2 lines follow
> [microtek] sane_init: config- #scsi * * Scanner
> [microtek] sane_init: config- #/dev/scanner
> [microtek] sane_init: config-
> [microtek] sane_init: config- #start of new lines
> [microtek] sane_init: config- scsi AGFA "StudioScan II" Scanner * * * *
> [microtek] attach_scanner: /dev/sga
> [microtek] attach_scanner: opening /dev/sga
> [microtek] attach_scanner: sending INQUIRY
> [microtek] id_microtek...
> [microtek] parse_inquiry...
> [microtek] parse_inquiry: does expanded-mode expansion internally.
> [microtek] dump_inquiry...
> === SANE/Microtek backend v0.12.0 ===
> ========== Scanner Inquiry Block ========mm
> 06 31 22 01 5b 00 00 00 41 47 46 41 20 20 20 20
> 53 74 75 64 69 6f 53 63 61 6e 20 49 49 20 20 20
> 32 2e 32 30 53 43 53 49 20 46 2f 57 56 33 2e 31
> 20 43 54 4c 35 33 38 30 03 4f 8c c5 00 ee 5b 03
> 01 01 02 00 00 03 00 01 00 4a 01 04 00 00 00 00
> 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ff
>
> ========== Scanner Inquiry Report ==========
> ===== Scanner ID...
> Device Type Code: 0x06
> Model Code: 0x5b
> Vendor Name: 'AGFA ' Model Name: 'StudioScan II '
> Vendor Specific String: 'SCSI F/WV3.1 CTL5380'
> Firmware Rev: '2.20'
> SCSI F/W version: 3.1 Scanner F/W version: 2.2
> Response data format: 0x01
> ===== Imaging Capabilities...
> Modes: Lineart Halftone Gray Color (OnePass)
> Resolution Step Sizes: 1% 5% Expanded Resolution Support? yes
> Supported Bits Per Sample: 4 8
> Max. document size code: 0x00
> Max. document size: 3399 x 5599 pixels
> Frame units: pixels 1/8"'s
> # of built-in halftones: 12 Downloadable patterns? Yes
> Data Compression:
> Contrast Settings: 14 Exposure Settings: 14
> Adjustable Shadow/Highlight? yes Adjustable Midtone? no
> Digital brightness/offset? no
> Gamma Table Size: 1024 entries of 1 bytes (max. depth: 8)
> ===== Source Options...
> Feed type: flatbed ADF support? yes
> Document Feeder Support? yes Feeder Backtracking? yes
> Feeder Installed? no Feeder Ready? no
> Transparency Adapter Installed? no
> Fast Color Prescan? no
> Selectable Transfer Format? no
> Color Transfer Sequence: line-by-line, non-sequential with headers
> Three pass scan support? yes
> ModeSelect-1 and ModeSense-1 Support? yes
> Can Disable Linearization Table? no
> Can Disable Start-of-Scan Recalibration? yes
> Internal expanded expansion? yes
>
>
> [microtek] attach_scanner: happy.
> [microtek] sane_init: config- #/dev/sga
> [microtek] sane_init: config-
> [microtek] sane_open
> [microtek] sane_open: find device...
> [microtek] sane_open: create scanner...
> [microtek] sane_open: initialize scanner dependent stuff...
> [microtek] sane_open: Real calibration enabled.
> [microtek] sane_open: init gamma tables...
> [microtek] sane_open: init pass-time variables...
> [microtek] sane_open: init clever cache...
> [microtek] sane_open: initialize options:
> [microtek] init_options...
> [microtek] init_options: quant yes
> [microtek] init_options: done.
> [microtek] sane_control_option (opt=0,act=0,val=0xbffff570,info=(nil))
> [microtek] sane_control_option (opt=0,act=0,val=0xbffff534,info=(nil))
> [microtek] sane_get_option_descriptor (0)...
> [microtek] sane_get_option_descriptor (1)...
> [microtek] sane_get_option_descriptor (2)...
> [microtek] sane_get_option_descriptor (3)...
> [microtek] sane_get_option_descriptor (4)...
> [microtek] sane_get_option_descriptor (5)...
> [microtek] sane_get_option_descriptor (6)...
> [microtek] sane_get_option_descriptor (7)...
> [microtek] sane_get_option_descriptor (8)...
> [microtek] sane_get_option_descriptor (9)...
> [microtek] sane_get_option_descriptor (10)...
> [microtek] sane_get_option_descriptor (11)...
> [microtek] sane_get_option_descriptor (12)...
> [microtek] sane_get_option_descriptor (13)...
> [microtek] sane_get_option_descriptor (14)...
> [microtek] sane_control_option (opt=14,act=0,val=0x804d818,info=(nil))
> [microtek] sane_get_option_descriptor (15)...
> [microtek] sane_control_option (opt=15,act=0,val=0x804d81c,info=(nil))
> [microtek] sane_get_option_descriptor (16)...
> [microtek] sane_get_option_descriptor (17)...
> [microtek] sane_get_option_descriptor (18)...
> [microtek] sane_get_option_descriptor (19)...
> [microtek] sane_get_option_descriptor (20)...
> [microtek] sane_get_option_descriptor (21)...
> [microtek] sane_get_option_descriptor (22)...
> [microtek] sane_get_option_descriptor (23)...
> [microtek] sane_get_option_descriptor (24)...
> [microtek] sane_get_option_descriptor (25)...
> [microtek] sane_get_option_descriptor (26)...
> [microtek] sane_get_option_descriptor (27)...
> [microtek] sane_get_option_descriptor (28)...
> [microtek] sane_get_option_descriptor (29)...
> [microtek] sane_get_option_descriptor (30)...
> [microtek] sane_get_option_descriptor (31)...
> [microtek] sane_get_option_descriptor (32)...
> [microtek] sane_get_option_descriptor (33)...
> [microtek] sane_control_option (opt=12,act=0,val=0xbffff530,info=(nil))
> [microtek] sane_control_option (opt=13,act=0,val=0xbffff530,info=(nil))
> [microtek] sane_control_option (opt=12,act=0,val=0xbffff56c,info=(nil))
> [microtek] sane_get_option_descriptor (14)...
> [microtek] sane_control_option
(opt=14,act=1,val=0xbffff568,info=0xbffff528)
> [microtek] sane_control_option (opt=13,act=0,val=0xbffff56c,info=(nil))
> [microtek] sane_get_option_descriptor (15)...
> [microtek] sane_control_option
(opt=15,act=1,val=0xbffff568,info=0xbffff528)
> [microtek] sane_start...
> [microtek] sane_get_parameters...
> [microtek] sane_get_parameters: regular 1-pass color
> [microtek] sane_get_parameters: res_code = 25 (19)
> [microtek] sane_get_parameters: dots_per_mm: 3.937008
> [microtek] sane_get_parameters: units_per_mm: 15.748031
> [microtek] WIDTHPIX: before exp: 850
> [microtek] sane_get_parameters: lines: 1400 ppl: 850 bpl: 2550
> [microtek] .wait_ready 4...
> [microtek] finagle_precal...
> [microtek] .compare_mode_sense 4...
> CMS: 0( 0) 64( 0) 8( 0) 1( 0) 7( 0) 7( 0) 0( 0) ff( 0) 80( 0) 7( 0)
> 7( 0) 0( 0) ff( 0) 80( 0) 7( 0) 7( 0) 0( 0) ff( 0) 80( 0)
> [microtek] finagle_precal: must precalibrate!
> [microtek] do_real_calibrate...
> [microtek] .start_calibrate...
> STCal:11 0 0 0 2 0 1 a
> [microtek] .get_scan_status 4...
> [microtek] get_scan_status(6): 1, 2058, 460545 -> #0
> [microtek] > 1 a 8 1 7 7
> [microtek] get_scan_status: busy, retry in 5...
> [microtek] get_scan_status(6): 1, 2058, 460545 -> #1
> [microtek] > 1 a 8 1 7 7
> [microtek] get_scan_status: busy, retry in 10...
> [microtek] get_scan_status(6): 1, 2058, 460545 -> #2
> [microtek] > 1 a 8 1 7 7
> [microtek] get_scan_status: busy, retry in 15...
> [microtek] get_scan_status(6): 1, 2058, 460545 -> #3
> [microtek] > 1 a 8 1 7 7
> [microtek] get_scan_status: busy, retry in 20...
> [microtek] do_real_cal: get_scan_status failed!
> [microtek] end_scan...
> scanimage: sane_start: Error during device I/O
> [microtek] sane_cancel...
> [microtek] end_scan...
> [microtek] sane_close...
> [microtek] sane_exit...
> [microtek] sane_exit: MICROTEK says goodbye.
>
>
> Finally I re read the man pages and remembered the lines about changing
> the params in the .conf file - I gave this a go - (stupidly I haven't got
> the details
> at work with me so can't post them accurately but changing the 2nd
paramater
> made no difference at all but the first one in the conf file seemed to get
a
> bit
> more action - the scanner burped and seemed as though it was trying to
start
> scanning....but then didn't and hung with an error message that suggested
> something similar to what the above output ie can't get device status....
>
> Anyone got any ideas or suggestions of what to look at next?
> Thanks
> JSW
>
>
>
> --
> Source code, list archive, and docs: http://www.mostang.com/sane/
> To unsubscribe: echo unsubscribe sane-devel | mail majordomo@mostang.com
>
-- Source code, list archive, and docs: http://www.mostang.com/sane/ To unsubscribe: echo unsubscribe sane-devel | mail majordomo@mostang.com