On Tue, Apr 17, 2001 at 10:02:39PM -0400, Tom Martone wrote:
>
> Greetings,
>
> The Bell+Howell driver supports the Copiscan II model 6338 which
> is rated at 42-50ppm at 200/240/300dpi. There's preliminary support
> for the 8000 series which have higher ratings (model 8080 65-80ppm,
> thru model 8125 100-125ppm at 200-400dpi). These are bilevel only,
> as far as I know. The 6338 is a duplex scanner and the 8000's are
> available as simplex or duplex.
>
> The installation that I'm working with has a 6338 and a 2137 and we
> have scanned over a million pages since November 1999. We should have
> a party :)
>
> The bh driver is in CVS and will be part of the next SANE release.
>
> Tom Martone
Tom,
Isn't the case that the B+H scanners will do bilevel only in SCSI, whereas
their own proprietary "video" interface will do greyscale? Do you know if
someone has a driver for their "video" interface under Linux?
Thanks,
Ajay
-- Source code, list archive, and docs: http://www.mostang.com/sane/ To unsubscribe: echo unsubscribe sane-devel | mail majordomo@mostang.com