Hi Henning,
>
> > kernel 2.4.3 + kernel 2.2.16:
> >
> > CVS Tree 1.11 + Mustek backendversion 1.0.105 (as delivered with the CVS
> > ) doesn't work for me. The scanner tries to scan beyond the physical
> > scanarea.
>
> I'm using Linux 2.2.18 at the moment with an Adaptec 2940. My scanner
> doesn't scan beyond the physical scan area at least not in the modes I
> tried. What did you do exactly? A preview scan or a full size scan?
> In which resolution and mode?
I tried to get the same error again, but I got different errors. I tried to
aquire
>
> I'm asking all these questions because I don't think I have changed
> anything concerning the Pro scanner between 104 and 105. But you never
> know...
>
> > To use the TA I had to hardcode the TA_flag in the sources. It seems,
> > that there is no special byte for the TA in the result string. But I may
> > be wrong.
>
> It's not in the inquiry information like for the other Mustek scanners
> but you can get the information from a "request sense" command. If a
> TA is present, byte 2 of the sense buffer is 0x40, otherweise it's 0.
> I have implemented that in my code but I'm not sure if it works. I
> think I sent you the source some hours ago. If it doesn't work because
> of the other problems maybe you can extract the detection cahnges and
> try them in 104.
>
> > If I use the 36 bit option it only works if I start xscanimage directly (
> > e.g. from a terminal box). Then the image is put directly into a file.
> >
> > Scanning with 36 bit with xscanimage as a gimp-plugin results in a KDE
> > error message, which says that KDE can't handle the output. ( may be due
> > to my KDE configuration)
>
> GIMP can't handle more than 8 bit/color. But you shouldn't get a
> message from KDE but from xsane.
>
> > kernel 2.2.17 - 2.2.19 :
> >
> > system hangs if I try scanning with the option quality calibration.
>
> This doesn't happen here. Maybe this one and the "out of scan area"
> problem are related to SCSI driver bugs? Can you test this with a
> different SCSI controller?
>
> Thanks for the report.
>
> Bye,
> Henning
>
>
> --
> Source code, list archive, and docs: http://www.mostang.com/sane/
> To unsubscribe: echo unsubscribe sane-devel | mail majordomo@mostang.com
-- Ulrich Hopp SEW-EURODRIVE GmbH & Co Siemenstr. 1 Technische Büro D-40764 Langenfeld Langenfeld Tel. +49-2173-8507-21 Mobil +49-172-2634678 Fax +49-2173-8507-50 http://www.sew-eurodrive.de-- Source code, list archive, and docs: http://www.mostang.com/sane/ To unsubscribe: echo unsubscribe sane-devel | mail majordomo@mostang.com