sane-umax-1.0.4-build-25 available

From: Oliver Rauch (oliver.rauch@rauch-domain.de)
Date: Sun Mar 04 2001 - 14:12:44 PST

  • Next message: Frederik Ramm: "Fujitsu M3091 driver released"

    Hi,

    sane-umax-1.0.4-build-25 is available.

    You can download it from:

            http://www.rauch-domain.de/sane-umax

    Bye
    Oliver

    CHANGES:

       * dev->lamp_control_available is preset to 0
     
       * dev is erased (0) after it is allocated
     
       * added special options for PowerLook 3000:
         - calibration is done for each CCD pixel
         - calibration_bytespp is set to 1
         the scanner still is not listed as supported scanner because
         the changes are not tested
     
       * added options that are read from umax.conf:
     
         - execute-request-sense:
           values: 0=disabled, 1=enabled, default=0
           If set to 1 umax_do_request_sense is called in umax_do_calibration.
           This can hang the system (but has been enabled until this version)
     
         - scsi-buffer-size-min, scsi-buffer-size-max:
           values: 4096-1048576, default min=65536, max=131072
     
         - scan-lines, preview-lines:
           values: 1-65535, default scan-lines=40, preview-lines=10
           define the maximum number of lines that are scanned into one buffer
     
         - force-preview-bit-rgb:
           values: 0=disabled, 1=enabled, default=0
           set preview bit in rgb real scan
     
         - slow-speed, care-about-smearing:
           values: -1=auto, 0=disabled, 1=enabled, default=-1
           dangerous options, needed for some scanners
     
         - calibration-full-ccd:
           values: -1=auto, 0=disabled, 1=enabled, default=-1
           do calibration for each pixel of ccd instead of selected image
     
         - calibration-width-offset:
           values: -1=disabled, >=0 set value
           add an offset width to the calculated with for image/ccd
     
         - calibration-bytes-pixel:
           values: -1=disabled, 0=not set, 1=1 byte/pixel, 2=x bytes/pixel
           use # bytes per pixel for calibration
     
         - invert-shading-data:
           values: -1=auto, 0=disabled, 1=enabled, default=-1
           invert shading data before sending it back to the scanner
     
         - lamp-control-available:
           values: 0=automatically set by driver - if known, 1=available, default=0
     
       * updated html-documentation
     
       * updated sane-umax.man
     
       * added pre focus options (PowerLook 3000):
         - FP - fix focus position
         - FDC - lens calibration in doc position
         - PF - disable pre focus
         - LCL - use 0.6/0.0mm holder focus position
     
       * added #define SANE_I18N(text) text to umax.c. This is to mark the backend
         specific texts that shall be translated by the frontend

    -- 
    Homepage:	http://www.rauch-domain.de
    sane-umax:	http://www.rauch-domain.de/sane-umax
    xsane:		http://www.xsane.org
    E-Mail:		mailto:Oliver.Rauch@rauch-domain.de
    

    -- Source code, list archive, and docs: http://www.mostang.com/sane/ To unsubscribe: echo unsubscribe sane-devel | mail majordomo@mostang.com