Re: Umax Astra 600S annoyance

Oliver Rauch (oliver.rauch@Wolfsburg.DE)
Wed, 22 Dec 1999 17:20:32 +0100

Gady Kozma wrote:

> Hi.
>
> I have an astra 600s and two scsi cards: a Tekram DC390 (IIRC) and an
> aha2940au. Under windows I can scan with the scanner connected to
> either. With sane/linux I can only use the scanner when it is connected
> to the aha2940. When the scanner is connected to the Tekram and I use
> xscanimage, the scanning line gets stuck mid-way and there is no visible
> output
>
> Its probably not related, but there are two other devices connected to
> the Tekram adapter. However, the scanner wouldn't work under linux even
> when connected directly to the Tekram. When connecting all three devices
> to the aha2940, none of the operating systems could use the scanner.
>
> Any ideas anyone? I'd love to free a PCI slot by dumping the other scsi
> adapter.
>

Hi Gady,

1) make sure the maximum cable length is not acceded
(150 cm if there are Ultra scsi device connected, 300 cm if only fast scsi devices are connected).
2) make sure the bus is terminated correct
3) make sure you took the right dirver for the scsi controller and you disabled reconnect/disconnect.
For the DC390 (its a symbios logic 53c8xx card - right - you sould try the bsd-53c8xx driver).

Bye
Oliver

--
Homepage:       http://www.wolfsburg.de/~rauch
sane-umax:      http://www.wolfsburg.de/~rauch/sane/sane-umax.html
xsane:          http://www.wolfsburg.de/~rauch/sane/sane-xsane.html
E-Mail:         mailto:Oliver.Rauch@Wolfsburg.DE

--
Source code, list archive, and docs: http://www.mostang.com/sane/
To unsubscribe: echo unsubscribe sane-devel | mail majordomo@mostang.com