Re: Astra 1220S problems

Mark Vojkovich (mvojkovi@ucsd.edu)
Mon, 17 May 1999 18:53:20 -0700 (PDT)

On Mon, 17 May 1999, Larry Snyder wrote:

> Hi Mark --
> I'm running the same scanner under 1.0.0 with no problems on an
> AS200-4/233 alpha box. It has a 53c810 scsi host. I'm using a
> 2.2.5 kernel. You might want to turn on debugging (see the archives)
> for any error messages, and verify terminations, etc.
> What box is this running on??? What architecture???
> Good luck!
> -ls-

Kernel 2.2.6 on a Dual 500MHz PIII system with dual
Symbios controlers (a 53c895 and a 53c810a). The scanner
is on the 53c810a controller and shows up fine in /proc/scsi.
I think it's terminated OK. I'll try turning debugging
info on and see if there are any errors. Could sheared
images be caused by bad termination? It's the only device
on that controller so I haven't had the opportunity to
if other devices are working OK.

MArk.

>
>
>
> Mark Vojkovich <mvojkovi@ucsd.edu> wrote:
> >
> > I have an UMAX Astra 1220S and have tried it with the
> > sane 0.71, 1.0.0 and 1.0.1 packages. It works, sortof.
> > The images it scans are badly sheared. This happens both
> > with scanimage and xscanimage. It even shows up sheared
> > in the preview window. I didn't find any problems mentioned
> > for this particular scanner on this list archive at all so
> > I am puzzled about this. Configuration problem?
> >
> > Any suggestions?
> >
> > MArk.
> >

--
Source code, list archive, and docs: http://www.mostang.com/sane/
To unsubscribe: echo unsubscribe sane-devel | mail majordomo@mostang.com