On Tue, May 19, 1998 at 09:07:19PM +0200, Oliver.Rauch@Wolfsburg.DE wrote:
> Hi David,
>
> > The latest release, sane-0.73, is finally available.
>
> I have a strange problem with sane-0.73.
[...]
> The last one I activated was the microtek2 backend,
> which prints
> 0: f000200000001f17 0000000000000000 .. ..... ........
> 16: 060802029c000000 554d41582020 ........ UMAX
> 0: f000200000003e17 0000000000000000 .. ...>. ........
> 16: 060802029c000000 554d41582020 ........ UMAX
I am very sorry for that. The problem is, that the attach() function,
which has already been improved in the meanwhile, recognizes that the
device is not a Microtek and returns an error to the calling function
( sane_init() ), but this function returns SANE_STATUS_GOOD
(as it should). There is still a logical mistake in this attach mechanism
and I know where and hope to get it fixed asap.
Sorry again,
Bernd
-- Bernd Schroeder Email: mailto:bernd@aquila.muc.de PGP public key available: mailto:pgp@aquila.muc.de | Subject: send key
-- Source code, list archive, and docs: http://www.mostang.com/sane/ To unsubscribe: echo unsubscribe sane-devel | mail majordomo@mostang.com