Re: Astra 6X0S colormode

Oliver.Rauch@Wolfsburg.DE
Mon, 9 Feb 1998 22:13:43 +0100 (MET)

Hello Nicolas,

> The new patch seems to work for Astra 610S too !
Thanks for that info!

> - The scan area apparently miss ~1 cm on the left side of the picture.
> (That is, the offset from left margin is ~1 cm greater than requested).
> No trouble with the top margin, nor with image width / height. If
> scanning the full width, the right margin end with a grey area, ~30-35
> pixel large, that look like the physical border of the scanner :-). This
> problem exists both in grey and color mode.
That is very strange! Did you have this problem in other sane-versions?

> - The PNM files produced by [x]scanimage miss some data at the end. For
> a 1299x1889 image, the file is 7330294 long, instead of 7361470
> (1299x1889x3+37 bytes of header). For a 330x586 image, the file is
> 572255 long, instead of 580175 (330x586x3+35 bytes of header). In both
> cases, we miss 8 whole lines of data. This problem exists only in color
> mode.
This should be solved in the new version on my homepage!

Bye
Oliver

--