Re: problems with mscan-0.1 and paragon 600IICD

Thomas Blume (mblum1@nightshift.uni-paderborn.de)
Mon, 26 May 1997 00:05:12 +0200

>
> Fritz> hi, i've been trying to get a mustek paragon II CD (should be
> Fritz> almost the same as paragon II SP) to run under linux with an
> Fritz> adaptec 1542 hostadapter. each time i invoke mscan, the
> Fritz> kernel reports the following error message:
>
> There were some reports of successful uses of the Paragon 600 II CD
> and it really seems to be compatible with the SP version. I don't
> know about the Adaptec 1542 but the AHA-1505 and AHA-2940 are reported
> to work fine, so I'd hope the same is true for the 1542 (can anybody
> confirm this?).
>
> Fritz> Wrong buffer length supplied for request sense (4)
>

Hi there,

since my problems with the 1542 were fixed with sane-0.57 (the problem
actually was an explicit call to request_sense), I assume the latest
version of sane will do the job for you. At least the combo
1200SP - AHA1542C works fine, and so it should do with the 600II-SP.
BTW: Is mscan still under development??

Thomas

-- 
Thomas Blume                          <mblum1@hrz.uni-paderborn.de>
Technische Chemie und Chemische Verfahrenstechnik, UNI-GH-Paderborn
Tel.: +49 5251 602598                          Fax: +49 5251 603244

--
Source code, list archive, and docs: http://www.azstarnet.com/~axplinux/sane/
To unsubscribe: mail -s unsubscribe sane-devel-request@listserv.azstarnet.com