Re: Canon 620 S Flatbed scanner

From: Mick Barry (mick@objects.com.au)
Date: Sat May 26 2001 - 21:23:00 PDT

  • Next message: Oliver Rauch: "corrected xsane-win32-0_77a released"

    Your advice did the track, we've move forward a couple of spaces.
    We're now getting the following error:

    [sanei_debug] Setting debug level of canon to 16.
    [canon] >> sane_init
    [canon] sane_init: sane-backends 1.0.4
    [canon] >> attach_one
    [canon] >> attach
    [canon] attach: opening b2t2l0
    [sanei_debug] Setting debug level of sanei_scsi to 255.
    [sanei_scsi] OS/2: installed adapters 3
    [sanei_scsi] OS/2: ASPI manager is 'OS2ASPI Dev Mgr ATA_ATAPI '
    [sanei_scsi] OS/2: host adapter is 'ATA_ATAPI '
    [sanei_scsi] OS/2: unique id is ''
    [sanei_scsi] open_aspi: open temporary file 'asa00076'
    [sanei_scsi] OS/2: adapter#00 'ATA_ATAPI '
    [sanei_scsi] OS/2: id#00 status=82h
    [sanei_scsi] OS/2: id#01 status=01h
    [sanei_scsi] OS/2: type is 'CD-drive'
    [sanei_scsi] OS/2 'RICOH CD-R/RW MP7083A
    1.20001108SECMA07008251 '
    [sanei_scsi] OS/2: id#02 status=82h
    [sanei_scsi] OS/2: id#03 status=82h
    [sanei_scsi] OS/2: id#04 status=82h
    [sanei_scsi] OS/2: id#05 status=82h
    [sanei_scsi] OS/2: id#06 status=82h
    [sanei_scsi] OS/2: adapter#01 'ATA_ATAPI '
    [sanei_scsi] OS/2: id#00 status=01h
    [sanei_scsi] OS/2: type is 'CD-drive'
    [sanei_scsi] OS/2 ' ATAPI 44X CDROM
    3.40001108SECMA07008251 '
    [sanei_scsi] OS/2: id#01 status=82h
    [sanei_scsi] OS/2: id#02 status=82h
    [sanei_scsi] OS/2: id#03 status=82h
    [sanei_scsi] OS/2: id#04 status=82h
    [sanei_scsi] OS/2: id#05 status=82h
    [sanei_scsi] OS/2: id#06 status=82h
    [sanei_scsi] OS/2: adapter#02 'ADPT AHA-2910 Ç'
    [sanei_scsi] OS/2: id#00 status=82h
    [sanei_scsi] OS/2: id#01 status=82h
    [sanei_scsi] OS/2: id#02 status=01h
    [sanei_scsi] OS/2: type is 'scanner'
    [sanei_scsi] OS/2 'CANON IX-06035E
    1.02001108SECMA07008251 '
    [sanei_scsi] OS/2: id#03 status=82h
    [sanei_scsi] OS/2: id#04 status=82h
    [sanei_scsi] OS/2: id#05 status=82h
    [sanei_scsi] OS/2: id#06 status=82h
    [sanei_scsi] open_aspi: close temporary file 'asa00076'
    [canon] attach: sending (standard) INQUIRY
    [canon] attach: sending TEST_UNIT_READY
    [canon] >> sense_handler
    [canon] canon_sense_handler(0, 0x295ef1e, 0)
    [canon] canon_sense_handler: no handling for sense f0.
    [canon] << sense_handler
    [canon] attach: sending RESERVE UNIT
    [canon] attach: sending GET SCAN MODE for scan control conditions
    [canon] scan mode byte[0] = 19
    [canon] scan mode byte[1] = 0
    [canon] scan mode byte[2] = 0
    [canon] scan mode byte[3] = 0
    [canon] scan mode byte[4] = 32
    [canon] scan mode byte[5] = 14
    [canon] scan mode byte[6] = 0
    [canon] scan mode byte[7] = 0
    [canon] scan mode byte[8] = 1
    [canon] scan mode byte[9] = 244
    [canon] scan mode byte[10] = 0
    [canon] scan mode byte[11] = 1
    [canon] scan mode byte[12] = 1
    [canon] scan mode byte[13] = 1
    [canon] scan mode byte[14] = 0
    [canon] scan mode byte[15] = 0
    [canon] scan mode byte[16] = 0
    [canon] scan mode byte[17] = 0
    [canon] scan mode byte[18] = 2
    [canon] scan mode byte[19] = 0
    [canon] scan mode byte[20] = 0
    [canon] scan mode byte[21] = 48
    [canon] scan mode byte[22] = 114
    [canon] scan mode byte[23] = 0
    [canon] scan mode byte[24] = 69
    [canon] scan mode byte[25] = 32
    [canon] scan mode byte[26] = 32
    [canon] scan mode byte[27] = 32
    [canon] scan mode byte[28] = 32
    [canon] scan mode byte[29] = 32
    [canon] scan mode byte[30] = 32
    [canon] scan mode byte[31] = 32
    [canon] scan mode byte[32] = 49
    [canon] scan mode byte[33] = 46
    [canon] scan mode byte[34] = 48
    [canon] scan mode byte[35] = 50
    [canon] scan mode byte[36] = 48
    [canon] scan mode byte[37] = 48
    [canon] scan mode byte[38] = 49
    [canon] scan mode byte[39] = 49
    [canon] scan mode byte[40] = 48
    [canon] scan mode byte[41] = 56
    [canon] scan mode byte[42] = 83
    [canon] scan mode byte[43] = 69
    [canon] scan mode byte[44] = 67
    [canon] scan mode byte[45] = 77
    [canon] scan mode byte[46] = 65
    [canon] scan mode byte[47] = 48
    [canon] scan mode byte[48] = 55
    [canon] scan mode byte[49] = 48
    [canon] scan mode byte[50] = 48
    [canon] scan mode byte[51] = 56
    [canon] scan mode byte[52] = 50
    [canon] scan mode byte[53] = 53
    [canon] scan mode byte[54] = 49
    [canon] scan mode byte[55] = 32
    [canon] scan mode byte[56] = 0
    [canon] scan mode byte[57] = 0
    [canon] scan mode byte[58] = 0
    [canon] scan mode byte[59] = 0
    [canon] scan mode byte[60] = 0
    [canon] scan mode byte[61] = 0
    [canon] scan mode byte[62] = 0
    [canon] scan mode byte[63] = 0
    [canon] scan mode byte[64] = 0
    [canon] scan mode byte[65] = 0
    [canon] scan mode byte[66] = 0
    [canon] scan mode byte[67] = 0
    [canon] scan mode byte[68] = 0
    [canon] scan mode byte[69] = 0
    [canon] scan mode byte[70] = 0
    [canon] scan mode byte[71] = 0
    [canon] scan mode byte[72] = 0
    [canon] scan mode byte[73] = 0
    [canon] attach: sending (extended) INQUIRY
    [canon] attach: sending MODE SENSE
    [canon] dev->sane.name = 'b2t2l0'
    [canon] dev->sane.vendor = 'CANON'
    [canon] dev->sane.model = 'IX-06035E '
    [canon] dev->sane.type = 'flatbed scanner'
    [canon] >> get tpu stat
    [canon] >> get adf stat
    [canon] bmu=0
    [canon] mud=600
    [canon] xres_default=600
    [canon] xres_range.max=600
    [canon] xres_range.min=75
    [canon] xres_range.quant=1
    [canon] yres_default=600
    [canon] yres_range.max=600
    [canon] yres_range.min=75
    [canon] xres_range.quant=1
    [canon] x_range.max=14157545
    [canon] y_range.max=19462116
    [canon] x_adf_range.max=-1
    [canon] y_adf_range.max=-1
    [sanei_scsi] OS/2: ASPI closed
    [canon] << attach
    [canon] << attach_one
    [canon] << sane_init
    [canon] >> sane_open
    [canon] >> init_options
    [canon] >> max_string_size
    [canon] << max_string_size
    [canon] >> max_string_size
    [canon] << max_string_size
    [canon] >> max_string_size
    [canon] << max_string_size
    [canon] >> max_string_size
    [canon] << max_string_size
    [canon] >> max_string_size
    [canon] << max_string_size
    [canon] >> max_string_size
    [canon] << max_string_size
    [canon] >> max_string_size
    [canon] << max_string_size
    [canon] << init_options
    [canon] << sane_open
    [canon] >> sane_start
    [canon] >> sane_get_parameters
    [canon] sane_get_parameters: width='5102', xres='300', mud='600'
    [canon] sane_get_parameters: length='7014', yres='300', mud='600'
    [canon] sane_get_parameters: pixels_per_line='2551', lines='3507'
    [canon] sane_get_parameters: xres='0', yres='0', pixels_per_line='2551',
    bytes_per_line='7653', lines='3507'
    [canon] << sane_get_parameters
    [sanei_debug] Setting debug level of sanei_scsi to 255.
    [sanei_scsi] OS/2: installed adapters 3
    [sanei_scsi] OS/2: ASPI manager is 'OS2ASPI Dev Mgr ATA_ATAPI '
    [sanei_scsi] OS/2: host adapter is 'ATA_ATAPI '
    [sanei_scsi] OS/2: unique id is ''
    [sanei_scsi] open_aspi: open temporary file 'asa00076'
    [sanei_scsi] OS/2: adapter#00 'ATA_ATAPI '
    [sanei_scsi] OS/2: id#00 status=82h
    [sanei_scsi] OS/2: id#01 status=01h
    [sanei_scsi] OS/2: type is 'CD-drive'
    [sanei_scsi] OS/2 'RICOH CD-R/RW MP7083A
    1.20001108SECMA07008251 '
    [sanei_scsi] OS/2: id#02 status=82h
    [sanei_scsi] OS/2: id#03 status=82h
    [sanei_scsi] OS/2: id#04 status=82h
    [sanei_scsi] OS/2: id#05 status=82h
    [sanei_scsi] OS/2: id#06 status=82h
    [sanei_scsi] OS/2: adapter#01 'ATA_ATAPI '
    [sanei_scsi] OS/2: id#00 status=01h
    [sanei_scsi] OS/2: type is 'CD-drive'
    [sanei_scsi] OS/2 ' ATAPI 44X CDROM
    3.40001108SECMA07008251 '
    [sanei_scsi] OS/2: id#01 status=82h
    [sanei_scsi] OS/2: id#02 status=82h
    [sanei_scsi] OS/2: id#03 status=82h
    [sanei_scsi] OS/2: id#04 status=82h
    [sanei_scsi] OS/2: id#05 status=82h
    [sanei_scsi] OS/2: id#06 status=82h
    [sanei_scsi] OS/2: adapter#02 'ADPT AHA-2910 Ç'
    [sanei_scsi] OS/2: id#00 status=82h
    [sanei_scsi] OS/2: id#01 status=82h
    [sanei_scsi] OS/2: id#02 status=01h
    [sanei_scsi] OS/2: type is 'scanner'
    [sanei_scsi] OS/2 'CANON IX-06035E
    1.02001108SECMA07008251 '
    [sanei_scsi] OS/2: id#03 status=82h
    [sanei_scsi] OS/2: id#04 status=82h
    [sanei_scsi] OS/2: id#05 status=82h
    [sanei_scsi] OS/2: id#06 status=82h
    [sanei_scsi] open_aspi: close temporary file 'asa00076'
    [canon] do_focus: sending GET FILM STATUS
    [sanei_scsi] sanei_scsi_cmd: command 0xe1 failed.
    [canon] do_focus: GET FILM STATUS failed
    [sanei_scsi] OS/2: ASPI closed
    [canon] attach: sending GET SCAN MODE for scan control conditions
    [sanei_scsi] sanei_scsi_cmd: DosDevIOCtl failed.
    [canon] scan mode control byte[0] = 0
    [canon] scan mode control byte[1] = 0
    [canon] scan mode control byte[2] = 0
    [canon] scan mode control byte[3] = 0
    [canon] scan mode control byte[4] = 0
    [canon] scan mode control byte[5] = 0
    [canon] scan mode control byte[6] = 0
    [canon] scan mode control byte[7] = 0
    [canon] scan mode control byte[8] = 0
    [canon] scan mode control byte[9] = 0
    [canon] scan mode control byte[10] = 0
    [canon] scan mode control byte[11] = 0
    [canon] scan mode control byte[12] = 0
    [canon] scan mode control byte[13] = 0
    [canon] scan mode control byte[14] = 0
    [canon] scan mode control byte[15] = 0
    [canon] scan mode control byte[16] = 0
    [canon] scan mode control byte[17] = 0
    [canon] scan mode control byte[18] = 0
    [canon] scan mode control byte[19] = 0
    [canon] attach: sending GET SCAN MODE for transparency unit
    [sanei_scsi] sanei_scsi_cmd: DosDevIOCtl failed.
    [canon] attach: GET SCAN MODE for transparency unit failed
    scanimage: sane_start: Invalid argument
    [canon] >> sane_cancel
    [canon] << sane_cancel
    [canon] >> sane_close
    [canon] >> sane_close
    [canon] >> sane_exit
    [canon] << sane_exit

    --
    Source code, list archive, and docs: http://www.mostang.com/sane/
    To unsubscribe: echo unsubscribe sane-devel | mail majordomo@mostang.com
    



    This archive was generated by hypermail 2b29 : Sat May 26 2001 - 21:19:05 PDT