Re: Mustek 1200 SP Pro + aha152x + linux 2.4.3 = success

From: Ulrich Hopp (hopp@terminal-beach.de)
Date: Mon Apr 02 2001 - 15:18:46 PDT

  • Next message: Jérôme Loisel: "8x14 Scanners?"

    Hi Henning,

    sorry, I made a mistake. It was the BUILD 1.102 of mustek.c which works for
    me.
    >
    > > kernel 2.4.3 + kernel 2.2.16:
    > >
    > > CVS Tree 1.11 + Mustek backendversion 1.0.105 (as delivered with the CVS
    > > ) doesn't work for me. The scanner tries to scan beyond the physical
    > > scanarea.
    >
    > I'm using Linux 2.2.18 at the moment with an Adaptec 2940. My scanner
    > doesn't scan beyond the physical scan area at least not in the modes I
    > tried. What did you do exactly? A preview scan or a full size scan?
    > In which resolution and mode?
    I tried to get the same error again, but I got a different error. I tried to
    aquire a preview but the scanner stops at the end of the scan without
    returning and the display is freezed. Switching the scanner off and on
    makes the computer usable again.
    >
    > I'm asking all these questions because I don't think I have changed
    > anything concerning the Pro scanner between 104 and 105. But you never
    > know...
    Of course you are right :-)
    > > To use the TA I had to hardcode the TA_flag in the sources. It seems,
    > > that there is no special byte for the TA in the result string. But I may
    > > be wrong.
    >
    > It's not in the inquiry information like for the other Mustek scanners
    > but you can get the information from a "request sense" command. If a
    > TA is present, byte 2 of the sense buffer is 0x40, otherweise it's 0.
    > I have implemented that in my code but I'm not sure if it works. I
    > think I sent you the source some hours ago. If it doesn't work because
    > of the other problems maybe you can extract the detection cahnges and
    > try them in 104.

    It works fine ( but merged into BUILD 1.102 ). I got your code just after
    sending this mail ...
    I'll make further investigations next weekend.

    > > kernel 2.2.17 - 2.2.19 :
    > >
    > > system hangs if I try scanning with the option quality calibration.
    >
    > This doesn't happen here. Maybe this one and the "out of scan area"
    > problem are related to SCSI driver bugs? Can you test this with a
    > different SCSI controller?
    sorry no different SCSI controller for testing available
    >
    > Thanks for the report.
    thanks for your code :-)

    see you

    --
    Source code, list archive, and docs: http://www.mostang.com/sane/
    To unsubscribe: echo unsubscribe sane-devel | mail majordomo@mostang.com
    