abel deuring wrote:
>
> The Umax backend is not the most trivial piece of software; while it
> tries to allocate a SCSI buffer of 128 kB when opening the SG file, I
> could not figure out, how much data is actually transferred with a
> single SCSI command. (Oliver, can you give a hint??)
>
Hi Abel,
it depends on the frame buffer of the scanner.
Most umax scanners use between 223KB and 2MB.
As far as I see this is the limit for the transfered data size of one scsi command
if the buffer is large enough. At least a single sanei_scsi_cmd() is able to
get several 100KBytes. (Tested with a PowerLookIII with 2MB framesize and
2MB scsi-buffer-size. Looks like a 2MB buffer does work).
Bye
Oliver
-- Homepage: http://www.wolfsburg.de/~rauch sane-umax: http://www.wolfsburg.de/~rauch/sane/sane-umax.html xsane: http://www.wolfsburg.de/~rauch/sane/sane-xsane.html E-Mail: mailto:Oliver.Rauch@Wolfsburg.DE-- Source code, list archive, and docs: http://www.mostang.com/sane/ To unsubscribe: echo unsubscribe sane-devel | mail majordomo@mostang.com
This archive was generated by hypermail 2b29 : Tue Apr 11 2000 - 12:51:59 PDT