More info concerning my preceding message.
Setting SANE_DEBUG_*
I get :
...>./scanimage -d coolscan:/dev/scanner
[sanei_init_debug]: Setting debug level of dll to 128.
sanei_config_open: attempting to open `./dll.conf'
sanei_config_open: attempting to open
`/opt/exec/sane/etc/sane.d/dll.conf'
sanei_config_open: using file `/opt/exec/sane/etc/sane.d/dll.conf'
adding backend net
...already there
adding backend abaton
...already there
adding backend agfafocus
...already there
adding backend apple
...already there
adding backend artec
...already there
adding backend canon
...already there
adding backend coolscan
...already there
adding backend dmc
...already there
adding backend epson
...already there
adding backend hp
...already there
adding backend microtek
...already there
adding backend microtek2
...already there
adding backend mustek
...already there
adding backend pint
adding backend qcam
adding backend ricoh
...already there
adding backend s9036
...already there
adding backend sharp
...already there
adding backend snapscan
...already there
adding backend tamarack
...already there
adding backend umax
...already there
init: initializing backend `coolscan'
[sanei_init_debug]: Setting debug level of coolscan to 128.
sane_init
sanei_config_open: attempting to open `./coolscan.conf'
sanei_config_open: attempting to open
`/opt/exec/sane/etc/sane.d/coolscan.conf'
sanei_config_open: using file `/opt/exec/sane/etc/sane.d/coolscan.conf'
sanei_scsi_find_devices: not implemented for this platform
attach_scanner: /dev/scanner
attach_scanner: opening /dev/scanner
[sanei_init_debug]: Setting debug level of sanei_scsi to 128.
identify_scanner
do_inquiry
000: 12 00 00 00 24 00
sanei_scsi_cmd: scmd.rw = 1, scmd.cdblen = 6, scmd.cdb =
{0x12,0x0,0x0,0x0,0x24,0x0, ...}
sanei_scsi_cmd: dst = {0x6,0x80,0x2,0x2,0x1f,0x0, ...}
sanei_scsi_cmd: returning 0x00000009
sanei_scsi_cmd: returning 36 bytes:
000: 06 80 02 02 1f 00 00 00 4e 69 6b 6f 6e 20 20 20
016: 43 4f 4f 4c 53 43 41 4e 49 49 49 20 20 20 20 20
032: 31 2e 32 30
get_inquiry_values
Found Nikon scanner COOLSCANIII version 1.20 on device /dev/scanner
attach_scanner: scanner-identification failed
sane_open
attach_scanner: /dev/scanner
attach_scanner: opening /dev/scanner
[sanei_init_debug]: Setting debug level of sanei_scsi to 128.
identify_scanner
do_inquiry
000: 12 00 00 00 24 00
sanei_scsi_cmd: scmd.rw = 1, scmd.cdblen = 6, scmd.cdb =
{0x12,0x0,0x0,0x0,0x24,0x0, ...}
sanei_scsi_cmd: dst = {0x6,0x80,0x2,0x2,0x1f,0x0, ...}
sanei_scsi_cmd: returning 0x00000009
sanei_scsi_cmd: returning 36 bytes:
000: 06 80 02 02 1f 00 00 00 4e 69 6b 6f 6e 20 20 20
016: 43 4f 4f 4c 53 43 41 4e 49 49 49 20 20 20 20 20
032: 31 2e 32 30
get_inquiry_values
Found Nikon scanner COOLSCANIII version 1.20 on device /dev/scanner
attach_scanner: scanner-identification failed
scanimage: open of device coolscan:/dev/scanner failed: Invalid argument
exiting
calling backend `umax's exit function
sane_exit
calling backend `tamarack's exit function
calling backend `snapscan's exit function
sane_snapscan_exit
calling backend `sharp's exit function
<< sane_exit >>
calling backend `s9036's exit function
calling backend `ricoh's exit function
>> sane_exit
<< sane_exit
calling backend `mustek's exit function
calling backend `microtek2's exit function
sane_exit:
sane_get_devices: local_only=0
sane_get_devices: sd_list_freed
sane_exit: MICROTEK2 says goodbye.
calling backend `microtek's exit function
sane_exit...
sane_exit: MICROTEK says goodbye.
calling backend `hp's exit function
exit called
calling backend `epson's exit function
calling backend `dmc's exit function
calling backend `coolscan's exit function
sane_exit
calling backend `canon's exit function
>> sane_exit
<< sane_exit
calling backend `artec's exit function
sane_exit
calling backend `apple's exit function
calling backend `agfafocus's exit function
calling backend `abaton's exit function
calling backend `net's exit function
exiting
calling backend `pnm's exit function
calling backend `dc25's exit function
-- Robert Nadot Professeur en Sciences de l'information Université de Bretagne-Sud tél: 02 97 01 26 83 1, rue de la Loi fax: 02 97 01 26 10 F-56000 VANNES émail: Robert.Nadot@univ-ubs.fr --------------DC46FB4801600D153C674C9D Content-Type: text/x-vcard; charset=us-ascii; name="Robert.Nadot.vcf" Content-Transfer-Encoding: 7bit Content-Description: Card for Robert Nadot Content-Disposition: attachment; filename="Robert.Nadot.vcf"begin:vcard n:Nadot;Robert x-mozilla-html:FALSE version:2.1 email;internet:Robert.Nadot@univ-ubs.fr x-mozilla-cpt:;0 fn:RobertNadot end:vcard
--------------DC46FB4801600D153C674C9D--
-- Source code, list archive, and docs: http://www.mostang.com/sane/ To unsubscribe: echo unsubscribe sane-devel | mail majordomo@mostang.com