Re: HP 4C Scanner and SANE

Andreas Dilger (adilger@enel.ucalgary.ca)
Tue, 2 Mar 1999 11:49:40 -0700 (MST)

Tony writes:
> I have a HP Scanjet 4c I am trying to use under FreeBSD 2.2.8. I have it
> connected to an Adaptec AHA 1510A SCSI card. The scanner is terminated
> as are the internal bus connectors.
[much grief deleted]

Is it possible that you have TOO MUCH termination? Often the external
connector and one internal connector are the same wires, so you only
need termination on one of them. In your case, it would be at the
scanner where the termination goes. I don't think the 1510 has two
separate SCSI busses (if it is like the 1505 or 1542), so there should
only be 2 terminiators involved. Otherwise, you will have erratic
problems with SCSI, and some things will work, while others won't.

Cheers, Andreas

-- 
Andreas Dilger  University of Calgary \ "If a man ate a pound of pasta and
                Micronet Research Group \ a pound of antipasto, would they
Dept of Electrical & Computer Engineering \  cancel out, leaving him still
<http://www-mddsp.enel.ucalgary.ca/People/adilger/>    hungry?" -- Dogbert

--
Source code, list archive, and docs: http://www.mostang.com/sane/
To unsubscribe: echo unsubscribe sane-devel | mail majordomo@mostang.com