Microtek ScanMaker X6EL supported??

Brian E. Bothwell (brbothwe@cs.indiana.edu)
Tue, 22 Sep 1998 09:16:34 -0500 (EST)

I just got a Microtek ScanMaker X6EL (hanging off of a Adaptec AVA-2902
adapter, which shows up successfully as a Adaptec AIC-7850 and works with
the Zip drive on the same SCSI chain)

I set up SANE to use only the microtek and microtek2 backends, while the
scanner seems to be recognized, SANE still complains "no SANE devices
found".

Anyone had any luck with this model? It's a great scanner, and I would
love not to have to boot to Windoze95 to use it. I assume if their is no
support, this is due to the fact the X6EL is so new to the market.

*************************************************

Here is a debugging dump of the microtek and microtek2 backends
(one thing to note is the VENDOR string is ' ', and the model it
shows up as is '636EL')
----------------------------------------------------------------
[root@scruffy sane.d]# scanimage
[inquiry]
120000006000
[inquiryresult]
060002025b00000020202020202020207363616e6e657220363336454c202020312e3130980000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000
[inquiry]
120000006000
[inquiryresult]
060002025b00000020202020202020207363616e6e657220363336454c202020312e3130980000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000
[inquiry]
120000006000
[inquiryresult]
060002025b00000020202020202020207363616e6e657220363336454c202020312e3130980000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000
[inquiry]
120000006000
[inquiryresult]
060002025b00000020202020202020207363616e6e657220363336454c202020312e3130980000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000
[sanei_init_debug]: Setting debug level of microtek to 128.
[microtek] sane_init: MICROTEK says hello! (v0.9)
[microtek] sane_init: config- #Uncomment following line to disable
"clever precalibration" routines...
[microtek] sane_init: config- #noprecal
[microtek] sane_init: config- #scsi VENDOR MODEL TYPE BUS CHANNEL ID LUN
[microtek] sane_init: config- #scsi * * Scanner 0 0 6 0
[microtek] sane_init: config- scsi * * Scanner
[microtek] attach_scanner: /dev/sgd
[microtek] attach_scanner: opening /dev/sgd
[microtek] attach_scanner: sending INQUIRY
[microtek] id_microtek...
[microtek] id_microtek: (uses new SCSI II command set)

========== Congratulations! ==========
You appear to be the proud owner of a
brand-new Microtek scanner, which uses
a new SCSI II command set.

Try the `microtek2' backend instead.

[microtek] attach_scanner: device doesn't look like a Microtek
scanner.[microtek] dump_suspect_inquiry...
=== SANE/Microtek backend v0.9 ===
========== Scanner Inquiry Block ========mm
06 00 02 02 5b 00 00 00 20 20 20 20 20 20 20 20
73 63 61 6e 6e 65 72 20 36 33 36 45 4c 20 20 20
31 2e 31 30 98 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00

========== Scanner Inquiry Report ==========
===== Scanner ID...
Device Type Code: 0x06
Model Code: 0x00
Vendor Name: ' ' Model Name: 'scanner 636EL '
Firmware Rev: '1.10'
SCSI F/W version: 0.0 Scanner F/W version: 0.2
Response data format: 0x02

[microtek] attach_scanner: /dev/sgd
[microtek] attach_scanner: opening /dev/sgd
[microtek] attach_scanner: sending INQUIRY
[microtek] id_microtek...
[microtek] id_microtek: (uses new SCSI II command set)

========== Congratulations! ==========
You appear to be the proud owner of a
brand-new Microtek scanner, which uses
a new SCSI II command set.

Try the `microtek2' backend instead.

[microtek] attach_scanner: device doesn't look like a Microtek
scanner.[microtek] dump_suspect_inquiry...
=== SANE/Microtek backend v0.9 ===
========== Scanner Inquiry Block ========mm
06 00 02 02 5b 00 00 00 20 20 20 20 20 20 20 20
73 63 61 6e 6e 65 72 20 36 33 36 45 4c 20 20 20
31 2e 31 30 98 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00

========== Scanner Inquiry Report ==========
===== Scanner ID...
Device Type Code: 0x06
Model Code: 0x00
Vendor Name: ' ' Model Name: 'scanner 636EL '
Firmware Rev: '1.10'
SCSI F/W version: 0.0 Scanner F/W version: 0.2
Response data format: 0x02

[microtek] sane_init: config- /dev/scanner
[microtek] attach_scanner: /dev/scanner
[microtek] attach_scanner: opening /dev/scanner
[microtek] attach_scanner: sending INQUIRY
[microtek] id_microtek...
[microtek] id_microtek: (uses new SCSI II command set)

========== Congratulations! ==========
You appear to be the proud owner of a
brand-new Microtek scanner, which uses
a new SCSI II command set.

Try the `microtek2' backend instead.

[microtek] attach_scanner: device doesn't look like a Microtek
scanner.[microtek] dump_suspect_inquiry...
=== SANE/Microtek backend v0.9 ===
========== Scanner Inquiry Block ========mm
06 00 02 02 5b 00 00 00 20 20 20 20 20 20 20 20
73 63 61 6e 6e 65 72 20 36 33 36 45 4c 20 20 20
31 2e 31 30 98 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00

========== Scanner Inquiry Report ==========
===== Scanner ID...
Device Type Code: 0x06
Model Code: 0x00
Vendor Name: ' ' Model Name: 'scanner 636EL '
Firmware Rev: '1.10'
SCSI F/W version: 0.0 Scanner F/W version: 0.2
Response data format: 0x02

[microtek] sane_get_devices
scanimage: no SANE devices found
[microtek] sane_exit...
[microtek] sane_exit: MICROTEK says goodbye.

**********************************************

--