Re: Mustek Paragon 1200 SP Pro

Miguel Alvarez Blanco (miguel@carbono.quimica.uniovi.es)
Mon, 22 Jun 1998 20:21:51 +0200

Hi again!

I'm replying to my own message to note that:

a) my computer hanged due to the microtek2 module, not the mustek one
(many thanks to Bernd Schroeder),

b) the Mustek Paragon 1200 SP Pro is unsupported as of sane-0.73 (thanks
to Ulrich Hopp for pointing it to me)

However, thanks to a) I now can make a full report of debugging messages
that could help in b) becoming false (I hope). This is the output of
scanimage -d mustek:/dev/scanner with max debugging (I think that it is
just saying that, since it can't recognize the scanner, it will not even
give it a try):

# scanimage -d mustek:/dev/scanner
[sanei_init_debug]: Setting debug level of dll to 128.
[dll] adding backend mustek
[dll] loading backend mustek
[dll] dlopen()ing `/usr/local/lib/sane/libsane-mustek.so.0'
[dll] init: initializing backend `mustek'
[sanei_init_debug]: Setting debug level of mustek to 128.
[mustek] sane_init: strip-height set to 1 inches
[sanei_init_debug]: Setting debug level of sanei_scsi to 128.
[sanei_init_debug]: Setting debug level of sanei_scsi to 128.
[sanei_scsi] searched device is /dev/sga
[mustek] attach: opening /dev/sga as scsi device
[sanei_init_debug]: Setting debug level of sanei_scsi to 128.
[mustek] attach: sending INQUIRY
[sanei_scsi] scsi_req_enter: entered 0x804cee8
[sanei_scsi] sanei_scsi_req_wait: waiting for 0x804cee8
[sanei_scsi] sanei_scsi.issue: 0x804cee8
[sanei_scsi] sanei_scsi_req_wait: read 132 bytes
[mustek] scsi_wait_ready: sending TEST_UNIT_READY
[sanei_scsi] scsi_req_enter: entered 0x804cee8
[sanei_scsi] sanei_scsi_req_wait: waiting for 0x804cee8
[sanei_scsi] sanei_scsi.issue: 0x804cee8
[sanei_scsi] sanei_scsi_req_wait: read 36 bytes
[mustek] attach: firmware revision 2.01
[mustek] attach: unknown model `FS-1200SPPRO'
[mustek] attach: opening /dev/scanner as scsi device
[sanei_init_debug]: Setting debug level of sanei_scsi to 128.
[mustek] attach: sending INQUIRY
[sanei_scsi] scsi_req_enter: entered 0x804cee8
[sanei_scsi] sanei_scsi_req_wait: waiting for 0x804cee8
[sanei_scsi] sanei_scsi.issue: 0x804cee8
[sanei_scsi] sanei_scsi_req_wait: read 132 bytes
[mustek] scsi_wait_ready: sending TEST_UNIT_READY
[sanei_scsi] scsi_req_enter: entered 0x804cee8
[sanei_scsi] sanei_scsi_req_wait: waiting for 0x804cee8
[sanei_scsi] sanei_scsi.issue: 0x804cee8
[sanei_scsi] sanei_scsi_req_wait: read 36 bytes
[mustek] attach: firmware revision 2.01
[mustek] attach: unknown model `FS-1200SPPRO'
[mustek] attach: opening /dev/scanner as scsi device
[sanei_init_debug]: Setting debug level of sanei_scsi to 128.
[mustek] scsi_wait_ready: sending TEST_UNIT_READY
[sanei_scsi] scsi_req_enter: entered 0x804cee8
[sanei_scsi] sanei_scsi_req_wait: waiting for 0x804cee8
[sanei_scsi] sanei_scsi.issue: 0x804cee8
[sanei_scsi] sanei_scsi_req_wait: read 36 bytes
[mustek] attach: sending INQUIRY
[sanei_scsi] scsi_req_enter: entered 0x804cee8
[sanei_scsi] sanei_scsi_req_wait: waiting for 0x804cee8
[sanei_scsi] sanei_scsi.issue: 0x804cee8
[sanei_scsi] sanei_scsi_req_wait: read 132 bytes
[mustek] scsi_wait_ready: sending TEST_UNIT_READY
[sanei_scsi] scsi_req_enter: entered 0x804cee8
[sanei_scsi] sanei_scsi_req_wait: waiting for 0x804cee8
[sanei_scsi] sanei_scsi.issue: 0x804cee8
[sanei_scsi] sanei_scsi_req_wait: read 36 bytes
[mustek] attach: firmware revision 2.01
[mustek] attach: unknown model `FS-1200SPPRO'
scanimage: open of device mustek:/dev/scanner failed: Invalid argument
[dll] exiting
[dll] calling backend `mustek's exit function

Many thanks to all that responded, and I offer again my help in testing
any modifications to sane-0.73's mustek backend to support the 1200 SP
PRO.

Thanks again,

Miguel

---
 Miguel Alvarez Blanco

E-mail: miguel@carbono.quimica.uniovi.es HomePage: http://www.uniovi.es/~quimica.fisica/qcg/mab/miguel.html Mail: Dpto. Quimica Fisica y Analitica, Universidad de Oviedo. Facultad de Quimica, c/ Julian Claveria, 8. 33006-Oviedo, Spain. Phone: +34 8 510 2975 Fax: +34 8 510 3125 Dpt.Office: +34 8 510 30 34

Never underestimate the bandwidth of a station wagon full of mag tapes. -- Dennis Ritchie

--
Source code, list archive, and docs: http://www.mostang.com/sane/
To unsubscribe: echo unsubscribe sane-devel | mail majordomo@mostang.com