Re: Agfa Arcus

Matto Marjanovic (maddog@mir.com)
Wed, 27 May 1998 01:40:12 -0400 (EDT)

Unfortunately, I would guess that the Agfa "Arcus" is not related to
the other Microtek(1) scanners (even though "Arcus II" is).

The two big clues are:
1) The Microtek documentation refers to "Arcus II", but not "Arcus".
2) In the inquiry data you obtained...
> ========== Scanner Inquiry Report ==========
> ===== Scanner ID...
> Device Type Code: 0x06
> Model Code: 0x50 <----------------------[modified by you...]
> Vendor Name: 'AGFA ' Model Name: 'ARCUS '
> Firmware Rev: 'V2.3'
> SCSI F/W version: 0.0 Scanner F/W version: 0.2
> Response data format: 0x02
...the scanners claims to use a SCSI-II command set ("0x02").
All the Microtek(1) scanners indicate "0x01".

Perhaps Agfa outsourced this device from another company, and it uses the
same command set as another backend?

-matt m.

--