Re: no mustek device - MFS6000SP

David Mosberger-Tang (davidm@azstarnet.com)
Tue, 13 May 1997 07:28:47 -0700

>>>>> On Tue, 13 May 1997 07:11:13 -0700, Andreas Gaumann <gg261@appl2.hrz.uni-siegen.de> said:

Andreas> Hello, since a view days I try to use sane-0.56 on a Mustek
Andreas> MFS-06000SP. (The SCSI-Controller is an ASUS SC200
Andreas> (NCR53c810)). But scanimage says that there is only the
Andreas> pnm-device. The mustek-device is not found. In the file

Does your system have a symlink from /usr/include/scsi to
/usr/src/kernel/include/scsi? If not, that would explain the problem.
Either create the symlink, or apply the sane-0.56-0.57.diff.gz patch,
then do "make distclean" and rebuild SANE.

--david

PS: The 0x7f characters in the inquiry result are normal for Mustek
scanners.

--