Re: MFS-12000CX

David Mosberger-Tang (davidm@azstarnet.com)
Wed, 16 Apr 1997 09:26:52 -0700

>>>>> On Mon, 14 Apr 1997 05:03:21 -0700, Matthias Lautner <lautner@hoggle.syscomp.de> said:

Matthias> - the kernel complains about "Wrong buffer length supplied
Matthias> for request sense (4)" but it still works; increase receive
Matthias> buffer to 16 ???

What SCSI driver are you using? Are you saying that with a buffer
size of 16 the warning/error message disappears?

Matthias> - the scanner MFS-12000CX (my version) needs the flag
Matthias> MUSTEK_FLAG_USE_EIGHTS to work, otherwise request_sense
Matthias> returns whith sense key 8 after the area command

OK, I fixed that---will be in the next release due out real soon.

Matthias> - scanning color doesn't work. The programm stops after one
Matthias> scan pass and the image file is corrupted. I didn't had
Matthias> time to check out yet :-)

I have fixed three more bugs in this area since the last release.
I.e., I'm working on it. But if you can debug the problem, it would
be of great help.

Matthias> - xscan often crashes with
Matthias> SIGSEGV when playing on controls, so I tested with scan

Probably a GTK bug. Pete fixed a lot of things and I fixed a few
things as well. As GIMP nears it's 1.0 release, these things should
disappear. Can you try the next GTK & SANE release when they become
available and see whether it fixes the problems you were seeing?

--david

--